Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wck domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6114
Reinforced and Reusable Silicone Laryngeal Mask
Show All Category
Endotracheal Tube, Cuffed

Reinforced and Reusable Silicone Laryngeal Mask

Reinforced and Reusable Silicone Laryngeal Mask

A laryngeal mask airway (LMA) is a supraglottic airway device developed by Arndt Schaldach in 1980. It consists of an oval silicone cup with a soft rubber flange at the top that sits above the glottis. The LMA is inserted through the mouth and into the pharynx where it forms a low-pressure seal around the base of the tongue to prevent aspiration.

Description
  • Soft, flexible tube with spiral reinforced wire reducing risk of kinking.
  • Designed for ENT, dental, oro-maxillary and eye surgery.
  • Autoclave sterilization only; Can be reused up to 40times.
Ref. No.: Size: Applicable people Qty. Cs:
NMR104222 1.0 <5kg 10
NMR104223 1.5 5-10kg 10
NMR104224 2.0 10-20kg 10
NMR104225 2.5 20-30kg 10
NMR104226 3.0 30-50kg 10
NMR104227 4.0 50-70kg 10
NMR104228 5.0 >70kg 10

Reinforced and Reusable Silicone Laryngeal Mask

A laryngeal mask airway (LMA) is a supraglottic airway device developed by Arndt Schaldach in 1980. It consists of an oval silicone cup with a soft rubber flange at the top that sits above the glottis. The LMA is inserted through the mouth and into the pharynx where it forms a low-pressure seal around the base of the tongue to prevent aspiration.

What is a reinforced and reusable silicone laryngeal mask?

A reinforced and reusable silicone laryngeal mask is a type of medical device that is used to provide a secure airway during certain medical procedures. The device consists of a mask, made of silicone, that fits over the larynx (voice box) and is connected to a tube that goes down the throat. The mask has a reinforcement band around the outside edge that helps to keep it in place and prevent it from being dislodged during use. The mask also has a valve on the side that allows for the release of air when needed.

How is it used?

The silicone laryngeal mask is a medical device that is used to provide a clear airway during medical procedures. It is also known as a supraglottic airway device. The silicone laryngeal mask is made of soft, pliable silicone that is inserted into the patient's mouth and placed over the larynx. The mask then seals around the larynx and provides a clear airway for the patient to breathe through. The silicone laryngeal mask can be reused multiple times and is often used in emergency situations where a clear airway is needed.

What are the benefits?

When it comes to airway management during anesthesia, the laryngeal mask airway (LMA) is a popular option due to its ease of use and low complication rate. But what if there was an LMA that was not only easy to use but could also be reused?

The reinforced and reusable silicone laryngeal mask (RRLM) is just such a device. The RRLM is made of medical grade silicone and has a metal reinforcement at the base that makes it sturdy and durable. It can be reused up to 40 times, making it a cost-effective option for both hospitals and individual clinicians.

The RRLM has all the benefits of a regular LMA, plus a few additional advantages. First, the reinforced base prevents the mask from collapsing during use, ensuring a secure airway. Second, the silicone construction makes the RRLM more comfortable for patients than other LMAs made of plastic or rubber. And third, the RRLM can be sterilized using standard methods, so there is no need for special cleaning or storage procedures.

If you are looking for an LMA that is easy to use, comfortable for patients, and cost-effective, the R

Are there any risks?

Yes, there are always risks associated with any medical procedure. However, the laryngeal mask is generally considered a very safe device. Complications are rare, but can include soreness or bruising in the throat, laryngeal spasm, and difficulty removing the device.

How to care for a reinforced and reusable silicone laryngeal mask

Assuming you have a reinforced and reusable silicone laryngeal mask, there are a few ways to care for it. The first way is to make sure that you clean the mask after each use. You can do this by using warm water and soap. Be sure to rinse the mask thoroughly. The next way to care for your mask is to store it in a clean, dry place. Be sure to keep it away from sunlight and extreme temperatures. Finally, inspect the mask regularly for any damage or wear and tear. If you notice any damage, be sure to replace the mask immediately.

Reinforced and Reusable Silicone Laryngeal Mask, Soft, flexible tube with spiral reinforced wire reducing risk of kinking. Designed for ENT, dental, oro-maxillary, and eye surgery, Autoclave sterilization only; Can be reused up to 40times. Nexgen Medical Company -shipping worldwide. Reinforced and Reusable Silicone Laryngeal Mask Reusable Reinforced Silicone Laryngeal Mask Reusable Reinforced Silicone Laryngeal Mask, Reusable Use Reinforced-Laryngeal Mask, Reusable Reinforced Silicone Laryngeal Mask, reinforced laryngeal mask, Reusable Reinforced Silicone Laryngeal Mask at low prices in India, Reusable Reinforced Silicone Laryngeal Mask Nexgen Medical shipping company.
  • the intubating LMA (Fastrach™) is a specially designed supraglottic airway device (SAD) that can be used as a conduit to facilitate intubation
USES
  • rescue device for failed intubation (i.e.. the “can’t intubate can ventilate” situation)
  • rescue devise for difficult bag-mask ventilation
  • a primary or alternate strategy for intubation
    • e.g. elective management of the known difficult airway
    • e.g. patients with known cervical spine injuries (ILMA use results in less spinal movement than direct laryngoscopy)
DESCRIPTION
  • a rigid curved airway tube
  • rigid handle for one-handed insertion in any patient position and helps ensure appropriate alignment
  • air-filled LMA cuff with epiglottic elevator bar
  • dedicated wire-reinforced silicone tracheal tube with low volume high-pressure cuff, ranging in sizes from 6.0 to 8.0 mm internal diameter
  • Stabilizing rod
  • Single-use and reusable models
  • Sizes 3 (30-50kg; 20mL cuff), 4 (50-70kg; 30 mL cuff) and 5 (70-100kg; 40 mL cuff)
METHOD OF INSERTION/ USE Insert ILMA
  • deflate ILMA cuff
  • lubricate ILMA mask on the posterior surface using water-soluble lubricant and rub the lubricant over the anterior hard palate
  • release cricoid pressure (if present) prior to inserting the LMA
  • insert ILMA holding the handle in a circular movement, maintaining contact against the curve of the palate and posterior pharynx
  • Never use the handle as a lever
  • release handle then inflate LMA cuff to a pressure of approximately 60 cm H2O (usually less than maximum cuff capacity)
Optimize position for intubation
  • Grasp the handle of the device and gently ventilate the patient
  • Squeezing the bag, and gently rotating the handle in and out and side to side until ventilation is optimized
  • Gently lift the handle anteriorly (in a similar fashion as a laryngoscope) and begin passing the lubricated ETT
Placement of an endotracheal tube
  • Hold the ILMA device handle while gently inserting the lubricated ETT into the airway shaft
  • Advance the ETT, inflate the cuff, and confirm intubation using ETCO2
Removal of the ILMA, leaving the endotracheal tube in position
  • Remove the ETT connector and ease the ILMA out by gently swinging the handle caudally
  • Use the stabilizing rod to keep the ETT in place while removing the ILMA until the ETT can be grasped at the level of the incisors
  • Remove the stabilizing rod and gently unthread the inflation line and pilot balloon of the ETT
  • Replace the ETT connector
  • NB. ETT is often in too deep following insertion via an ILMA, ETT often needs to be pulled back (check the distance at the teeth and confirm on CXR)